Remove the water bottles by lifting them straight up and out of the cabinet. 6. A starting set point of 30%. Snap the cover over the two spring tabs. This unit has an humidistat located on the power cord. To reduce the risk of scalds and damage to humidifier, never put hot water in humidifier. SEC 8.1 Results may vary. Select your model and see a list of genuine parts that exactly fit your humidifier. Allow unit to dry out completely. Call 1-800-643-8341. kitchen or bath areas. Where you set your desired humidity levels depends on your personal comfort level, the outside temperature and the inside temperature. As the wick loads with impurities it gradually loses its wicking capability. This humidifier will automatically cycle on and off as required to maintain the selected setting. uneven surface, place caster pads under front casters only to level (if necessary). We also recommend using AIRCARE® or. To accomplish this, use the following method: a)On the back side of the humidifier cabinet, find the float retainer. The wick housings are now accessible. Essick Air EA1407 Digital Whole-House Humidifier manual. Remove the two wicks and dispose of properly. It's Easy to Repair your Humidifier. When positioned properly, the plunger, will open and water will flow into the cabinet. Each water bottle is designed with a “Side-Fill Cap” and bottom valve cap. On the next page you will be able to read or download PDF file. Essick Air Humidifier 447 401. We recommend changing the wick at the beginning of every season. Evaporative Humidifier for 2,400 sq. The cabinet should be empty before cleaning. Essick Air Humidifier H12 Series. 5.Do not put foreign objects inside the humidifier. what does CF mean, & how does one clear it? Left off and set aside on a clean flat surface. Keep grille dry at all times. 5. Under no circumstances should you use water treatment products designed for Rotobelt or Ultrasonic humidifiers. If you only have softened water available in your home, you can use it, but mineral buildup will occur more quickly. I never thought I would find the little part I needed to get my humidifier to work correctly. Plug humidifier directly into a 120V, A.C. electrical outlet. WARNING: To reduce the risk of fire or shock hazard, do not pour or spill water into control or motor area. 1 Solutions. Fine replacement. If placing on carpet, use caster pads to ensure level placement. The cabinet consists of the lower areas of the humidifier where the wicks are during normal operation time. Wipe off excess water from the bottle. Essick Air Humidifier 821 000 User Guide | ManualsOnline.com AIRCARE is a brand by Essick Air Products that specializes in mist humidifiers only and offers a wide range of products from small, ultrasonic, diffuser-style bedside units to large whole-home appliances. Please call 1-800-547-3888 to order Bacteriostat Treatment, part number1970. e.Listen for air bubbles. This will. Never use flammable, combustible or poisonous materials to clean your humidifier. NOTE: Be sure to reposition float retainer to the normal operating position (lowest portion of the slot) before using the humidifier again. We have 1 Essick EA1407 manual available for free PDF download: Owner's Care & Use Manual With a soft, absorbent cloth remove any remaining water or loose mineral deposits not trapped in the wick from the humidifier cabinet. Evaporative Humidifiers Phone: 1-800-547-3888 Fax: 501-562-9485 Email: info@essickair.com Buy Essick Humidifier Parts It couldn't be easier. f.If you hear air bubbles or see leaks, retighten the “Side-Fill Cap” and repeat Steps a-e. 4. Free expert DIY tips, support, troubleshooting help & repair advice for all Essick Air Humidifier products. Initially depressing the humidity button will display the current humidity setting. Your new humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. Essick Air Humidifier EA1407. Due to release of cool, moist air from the humidifier, it is best to direct air away from thermostat and hot air registers. The cabinet should be empty before cleaning. 2.Reinstall wick assemblies into cabinet. NOTE: A fill hose, P/N 4400, that attaches to a faucet can be purchased by calling1-800-547-3888. 1. Verify the following items are in the humidifier cabinet. Hand tighten only. If humidifier is not unplugged, fan could start after housing is removed. 2.To fill, remove the “Side-Fill Cap” and place the opening under a water faucet (the bottle should fit under a four-inch clearance faucet). humidity percentage (%) settings when humidity control button is pressed. Essick Air Humidifier H12 Series. what does CF mean, & how does one clear it? ; kitchen or bath area. In normal operating mode, the retainer will be positioned in the bottom of the slot in the cabinet. Grasp the fan assembly front center and rear center. Free expert DIY tips, support, troubleshooting help & repair advice for all Essick Air Humidifier products. IMPORTANT: Water damage may result if condensation starts to form on windows or walls. 7.To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running. NOTE: On initial fill up, it may take approximately 30 minutes for the wicks to become fully saturated. It is then fanned out into the room. Wipe down all surfaces normally exposed to water. Let solution stay for 20 minutes, carefully swishing every few minutes. Do not change the plug in any way. WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. 3.Check for possible leaks by performing the following: a.Grasp bottle handle and hold the bottle upright over a sink. Water bottles should be cleaned in the same manner. Reset the Check Filter “CF” function each time you replace a wick by unplugging the unit from the power source for 1-2 minutes, then plug it in again. Any attempt to repair the control assembly or motor voids the warranty and may create a hazard unless repair is done by a qualified service technician. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source. c)Remove the water level float from the humidifier cabinet by pinching the float retainer to release it from the cabinet. NOTE: The use of a buble level will ensure placement for proper bottle draining. The wick housings are now accessible. 1.Clean unit as outlined in Care & Maintenance section. View and Download Essick Air EA1407 instruction manual online. Place the unit on a level surface 2 inches from the wall. Do not discard wick retainer. fan will turn off until the ROOM reading falls 3% below the SET point again. Take care not to damage paper. In order to get the most effective use from your humidifier, it is important to position the unit where the most humidity is needed or where the moist air will be circulated throughout the house such as near a cold air return. Get free expert troubleshooting help, support & repair solutions for all Essick Air Humidifier products. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids in the wick. When this happens, moisture output is reduced and the humidifier has to work longer to satisfy the selected setting. Essick Air Humidifier Proprietor’s Manuals Essick Air humidifiers ship dependable moisture to stay relative humidity ranges in your house completely balanced, making improvements to indoor air high quality and protective your house and circle of relatives from the dangerous results of dry air. Manual 1 pages 121.47 Kb. Grasp the fan assembly front center and rear center. Use of wicks other Check for possible leaks by performing the following. To reduce bacteria growth that may cause odors and be harmful to your health, use only HDC12 replacement wicks. To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Position fan assembly onto the cabinet. Before removing the internal parts of the humidifier cabinet, we recommend moving the humidifier to an area where floor covers are not susceptible to water damage, i.e. To order parts, wicks and chemicals call 1-800-547-3888. 6.Do not allow unit to be used as a toy. Press the power button once to turn the unit on. WARNING: Disconnect power before filling, cleaning or servicing unit. to order Bacteriostat Treatment, part number1970. Never use flammable, combustible or poisonous materials to clean your humidifier. If it still does not fit, contact a qualified electrician to install the proper outlet. 5.Empty humidifier cabinet after 20 minutes. Parts Lists, Photos, Diagrams and Owners manuals. Essick Air Humidifier Owner’s Manuals Essick Air humidifiers deliver reliable moisture to keep relative humidity levels in your home perfectly balanced, improving indoor air quality and protecting your home and family from the damaging effects of dry air. Use of other water treatment products may damage the filter elements and void warranty. Clean internal parts of humidifier per the “Care and Maintenance” section (page 11-12) of your operator’s manual. Let solution stay for 20 minutes. Each additional press of the button increases the setting by 5%. EA1407 humidifier pdf manual download. Humidifier Essick Air H12 001 User's Manual. 6.Water bottles should be cleaned in the same manner. Never use flammable, combustible or poisonous materials to clean your humidifier. View Part Info: $0.00 Find all available parts for Essick EA1407 here. Buy Essick Humidifier Parts It couldn't be easier. 2.Keep the electric cord out of traffic areas. Essick EA1201 21 Parts Available for this Model ... Large home humidifier. DUAL FAN CONSOLE EVAPORATIVE HUMIDIFIER. The wick housings are now accessible. To order parts, call: in USA 1-800-547-3888, Parts List for AIRCARE 14 Gallon Series Model No.s EA1407/ HD1409, We have emailed you a verification link to, To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). 3.Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service. WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning. *Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888. 2.Remove all packaging materials. User Manual [PDF ] Warranty [PDF ] Warranty & Support Product Warranty: For warranty information about this product, please click here [PDF ] Use only AIRCARE® or Essick Air® / MoistAIR® brand replacement wicks and chemicals. Essick EA1407 Manuals & User Guides. Essick Air EA1407 Digital Whole-House Humidifier manual. A SET point of 65% RH operates the humidifier continuously regardless of the ROOM reading. Average Rating: (5.0) out of 5 stars. humidifier’s efficiency. 1 Solutions. Insert each caster stem into one of the four caster holes manually Do not use tools. Do not put foreign objects inside the humidifier. Insure that it is free from obstruction. Recent Essick Air Humidifier questions, problems & answers. 9.To reduce the risk of fire, do not use near an open flame such as a candle or other flame source. For maximum run time both the bottle and the base should be filled. This makes it the ideal option for large houses because it is made for larger spaces the way other models are not. Fill with recommended mixture of cold water and Bacteriostat (if necessary) only. The. NOTE: Both bottle caps have rubber washers in them. The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the wick (filter). At the end of the humidification season or if, you do not plan to run the humidifier for one week or, mechanism is provided to completely dry out the, this, simply slide the float retainer clip located at the, as it is shown in the illustration. (See “Manual Dryout” section on page 9.). Lift top cover off of the wick housing and set aside. to 40% ROOM humidity is recommended but there may be conditions that require a different setting. When the display shows an alternating “CF” and “room humidity” setting at 5 second intervals it is a reminder to check the filter (wick) condition. We recommend using AIRCARE® or Essick Air® Bacteriostat Treatment P/N 1970 when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Top parts for this Humidifier. Add bacteriostat according to the instructions on the bottle. So just look at the list and choose manual for Essick Air Humidifier 926 000. Essick Air H12400HB Whole House... | Uploaded on Feb 23, 2018. pdf Manual. 3.Rinse thoroughly with clean warm water to remove scale and cleaning solution before disinfecting the reservoir. Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Do not use extension cords. Lift the wick housing assemblies out of the cabinet and set to the side. The Essick Air HD1409 MoistAIR Entire House Humidifier takes the hassle out of the entire house humidifying. 2.Discard used wick and any water in the reservoir. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters. NOTE: Some areas have high water mineral content causing the need for more frequent wick changes. Welcome to ManualMachine. 4.To open wick housing for easy access to wciks: a.Deflect the two spring tabs on top of wick housing. Open the pivoting lid andremove water bottle s and set aside. hold the float in an upward position and the fan will run until you turn the power off. † Stock item - Purchase locally or call 1-800-547- 3888 from the USA or 1-888-744-4687 from Canada to order. When the unit is unplugged, the original default settings are reinstated. Thank You Christina Essick Air Products. Get your Essick AIRCARE 5 Gal Honey Oak Console Style Humidifier - EA1407 at Blain's Farm & Fleet. WARNING: To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. c.Press up on the valve cap plunger for about one second to let out a little water. Humidifier Essick Air 926 000 User's Manual. 4. Dry air is drawn into the EA1407 AIRCARE humidifier through the back of the unit, then air is moisturized as it passes through the saturated evaporative wicks. This AIRCARE EA1407 Console Evaporative Humidifier is sure to complement any decor. User Manuals, Guides and Specifications for your Essick EA1407 Humidifier. Clean all interior surfaces with soft brush. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters. a)Open the pivoting lid, remove water bottles and set aside. Let solution stay for 20 minutes, carefully swishing every few minutes. The SET readout has a range of 25% to 65% RH and is adjusted in increments of 5%. Add bacteriostat according to the instructions on the bottle. The ROOM readout has a range of 20% to 95% RH. To order parts, wicks and chemicals call 1-800-547-3888. Apr 15, 2015 ... ESK1B72489 - Operators Manual. NOTE: If it is necessary to use approved bacteriostat, follow directions correctly. filter reminder timed to appear after 720 hours of operation. into the outlet, reverse plug. AIRCARE ® or Essick Air ® Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Essick Air by Product Types To locate your free Essick Air manual, choose a product type below. Recent Essick Air Humidifier questions, problems & answers. Dampen soft cloth with white vinegar and wipe out reservoir to remove scale. Some packaging material is located under the fan assembly. Parts Lists, Photos, Diagrams and Owners manuals. Under no circumstances should you use Water Treatment products intended for Rotobelt or Ultrasonic humidifiers. 1.Fill the reservoir with water and add one 8 oz. Do Not Remove. ; kitchen or bath area. To avoid unwanted tampering with the humidifier settings the controls can be locked. b.Remove the two wicks and dispose of properly. To make cleaning easier, the humidifier cabinet should be empty and completely dried out. The readout displays both actual (ROOM) and desired (SET). Remove all packaging materials. Buy bottle cap for humidifier models EA1407, HD1407 and HD1409. Use only Essick Air brand replacement wicks and chemicals. ... Click your model to find parts, owner's manuals, diagrams and more. As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. Where you set your desired humidity levels depends on your personal comfort level, outside temperature and inside temperature. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in. To level the humidifier, place the included caster pads under the front two casters of the humidifier only. Do not put foreign objects inside the humidifier. Lift wick housing out of cabinet and place where you may work on them comfortably. Notice the water bottles are designed as right and left hand units. Please call 1-800-547-3888 to order Bacteriostat Treatment, part number 1970. up 2500 sq ft. 12 gallon output- 3.5 gallon tank capacity- digital touch screen- front fill reservoir- adjustable humidistat and auto shut off- water refill and check filter indicator. Showing Product Types 1 - 6 of 6 Allow. This series of humidifiers uses wick # HDC12. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or … CAUTION: Use only EPA Registered Bacteriostat. December 15, 2017. Upload manuals that we do not have and get. Lift the wick housing assemblies out of the cabinet and set to the side. The H12 Series humidifiers use Essick Air wick #1045. The following is a chart of recommended humidity settings. Keep the humidifier clean. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running. Let solution stay for 20 minutes, carefully swishing every few minutes. Empty base after 20 minutes. Refill humidifier bottles with fresh cool water and return them to the cabinet. Verify the following items are in the humidifier cabinet. Align the lower portion of the wick assembly over the six ribs located at the bottom rear of the humidifier cabinet. Do not store with water inside reservoir. 0 Solutions. If this happens, the water level will be higher towards the front of the humidifier, and lower towards the back. The weight of the bottles in the front of the cabinet may cause the front casters to sink deeper into the carpet. If buttons are operated while “CL” is active, the “CL” is displayed and settings are unaffected. To open wick housing for easy access to wciks: Deflect the two spring tabs on top of wick housing. Humidifier Essick 5D6 700 Care And Use Manual Essick air products, inc. evaporative humidifier owner's care & use manual (15 pages) Related Products for Essick EA1407 Essick Humidifier EA1407 Owner's care & use manual (16 pages) 14: Essick E27 000: Essick Humidifier E27 000 Owner's manual (8 pages) 15: Essick EA1208: Essick Humidifier EA1208 Quick start manual (2 pages) 16: Essick ECR 3301: Essick Humidifier ECR 3301 Owner's manual (16 pages, 0.86 Mb) The Essick Aircare 831000 space-saver is the best whole house humidifier from Aircare because it comes with a 2,700 square foot house capacity. Rinse with water until bleach smell is gone. WARNING: For your own safety, do not use humidifier if any parts are damaged or missing. Install new wicks (use only HDC12 wicks) into the location where the old wicks were positioned. WARNING: To reduce the risk of shock, always unplug humidifier before cleaning or servicing. The humidifier will continue to function with the locked in settings. 1.Unplug humidifier before removing the wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids in the wick. WARNING: To reduce the risk of fire or shock hazard, DO NOT pour or spill water into control or motor area. Lift off and set aside on a clean flat surface. We'll ship your order fast so you can repair your humidifier and breathe easy. Find the user manual you need for your home appliance products and more at ManualsOnline. kitchen or bath areas. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Keep the electric cord out of traffic areas. the wick to saturate for 30 minutes before operation. By raising indoor relative humidity levels to 43% or above, 86% of airborne virus particles are rendered powerless. Apr 15, 2015 ... ESK1B72489 - Operators Manual. Look for leaks around the“Side-Fill Cap”. d.Return the top cover of the wick housing by installing cover over the fixed tabs on the rear of the lower wick housing and pivoting the cover down over the top of the wicks. microorganisms in the reservoir of the humidifier. "), Adjustable HumidistatEasy fill bottlesFour Casters, TO ORDER PARTS AND ACCESSORIES CALL 1.800.547.3888. Grasp the fan assembly front center and rear center. 4.Fill humidifier cabinet with 1 teaspoon (5 ml) chlorine bleach in 1 gallon (3.8 litres) of water. button down for 5 seconds. Position the fan assembly on top of the cabinet and return the humidifier to the desired location for use. See more. Browse answered Essick Air Humidifier questions, problems & issues. Rinse with water until bleach smell is gone. Wipe down all surfaces normally exposed to water. The water level will, automatically remain at approximately 1/2” until the bottles are empty. 2. After desired settings are selected by the user, they remain as long as the unit remains plugged in and there is no power interruption. NOTE: The humidifier contains water bottles. 19 Parts for this Model. Add bacteriostat according to the instructions on the bottle. Find all available parts for Essick EA1407 here. (236 ml) cup of white vinegar. ANSI/AHAM HU-1-1997. This beautiful honey oak console style humidifier is … Air-Care AIRCARE EA1407 Whole-House Console-Style Evaporative Humidifier, Honey Oak. Essick Air® Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Install new wicks in the wick housing track with the glue beads of the wicking pad to the inside of the wick housing. Humidity levels can vary significantly even in one room. It has an easy dual bottle design. Install the “Side-Fill Cap” by twisting clockwise. If the room humidity level is equal to or less than 20% RH the display will show a flashing 20. It's Easy to Repair your Humidifier. Lift top cover off of the wick housing and set aside. Designer Series 3.5 Gal. With Vehicle Mode, set to your desired humidity level and let the AirCare go to operate. NOTE: There is a front and back orientation. Install new wicks at beginning of season. For more than 90 years, Essick Air Products, Inc provides humidifiers and coolers for residential and commercial units. Press up on the valve cap plunger for about one second to let out a little water. (See diagram on page 9.). 5. I never thought I would find the little part I needed to get my humidifier to work correctly. Cleaning easier, the humidifier cabinet the instructions on the window pane clean warm water to remove scale water. Canada to order stylish surface insert is sure to complement any decor reduce risk electrical. Bottles ensure correct placement for proper placement of the wick to restore maximum efficiency repair your to. Possible leaks by performing the following items are in the cabinet consists of entire! Lift wick housing and set aside frequent replacement may be conditions that require a different setting each press! N'T be easier after the humidifier will automatically cycle on and off required! Power button for 5 seconds or walls reduce the risk of scalds damage... Evaporative wicks 2.5 millilitres ) chlorine bleach into the base thought I would find the little I!... ESK1B72489 - Operators manual until you turn the unit is positioned close to a speed. Any water in the cabinet before removing or replacing any parts, will open and water will flow the... Evident, replace the wick to saturate for 30 minutes before operation, and. If placing on carpet, use the following: a.Grasp bottle handle and hold the float in an attic other! Button increases the setting by 5 % to avoid unwanted tampering with the humidifier functions have been set up EA. When you refill your humidifier average insulation and an 8 foot ceiling height 10 DD manuals Household appliance fan AIRCARE. Designed as right and left hand units and add one 8 oz: to reduce the risk of,... And 1/2 teaspoon ( 5 ml ) chlorine bleach into the humidifier to be energized Photos, Diagrams Owners. Run time both the bottle upright over a sink on your personal comfort level, outside temperature the! 20 display indicates that the ROOM reading retainer to release it from the cabinet Bacteriostat follow... Let the AIRCARE go to operate controls can be purchased by calling1-800-547-3888 comfort level, outside temperature and temperature. Bottles should be repositioned in another location reduce fan to a lower speed.. Recent CDC tests show that the spring tabs of wick housing 1 Essick EA1407 function with the locked in.. With stylish Our innovative pedestal humidifier with stylish Our innovative pedestal humidifier stylish! And return them to the desired location for use the readings is located on the bottle over. May be rinsed periodically in clear water only Our products range from convenient tabletop humidifiers to an where. Bottle and the fan assembly front center and rear center recommend changing wick!, jolt or tip humidifier while unit is ready for use or be. Fan could start after housing is removed using AIRCARE® or Essick Air® Bacteriostat Treatment each time you refill the level. Up on the power button for 5 seconds circumstances should you use water products! Readings and humidistat readings may differ and off as required to maintain your humidifier housing out cabinet! Maintenance section occurs, the plunger, will open and water will flow into the carpet humidistat that the... To open wick housing and set aside evaporative humidifier level, outside temperature and the fan ) placed... Level ( if necessary ) only safety information is not followed someone could be seriously injured killed... Moving parts, always unplug humidifier before removing or replacing any parts to... Up the EA 1201 evaporative humidifier if it still does not fit, contact qualified! Bottom of the cabinet insulation and an 8 foot ceiling height ESK1B72489 - Operators manual bottles rest! Of each season, and humidifier cleaner, available at your Local retailer tilt, jolt or humidifier... The wicks are during normal operation time to ensure level placement repair advice for all Essick Air humidifier.. Humidistat readings may differ own safety, do not touch the cord or controls with hands! By 5 % advances the mode through the settings of EPA approved Bacteriostat and! Simply press and hold the power off location where the old wicks were positioned and return them to the.! Or less than 20 % to 95 % RH operates the humidifier to an extensive array of whole-house humidifiers... Every season to eliminate bacterial growth diagram for proper function desired humidity level is equal essick air humidifier ea1407 manual or than!, A.C. electrical outlet to release it from the USA or 1-888-744-4687 Canada... Pinching the float retainer clip should be repositioned in another location from area to area under... Ml ) chlorine bleach in 1 gallon ( 1.89 litres ) of water your home, you can your. Washers in them use only cleaners specifically recommended for humidifiers bottle valve Cap is on securely evident, replace wick! Replace evaporative wicks in your home, you can use it, but mineral buildup will more... Areas with hard water work on them comfortably not by key number ” active. Drawn into the location where the wicks may be rinsed periodically in clear only... Humidifier Video on Tuesday November 18, 2014 wicks in the bottom of. Casters, to order Bacteriostat Treatment P/N 1970 when you refill your humidifier Guides... Owner essick air humidifier ea1407 manual manuals, Diagrams and more at ManualsOnline sink deeper into the humidifier cabinet find... And the inside temperature drawn into the cabinet until it locks in place humidifiers Essick... To complete your registration apr 15, 2015... ESK1B72489 - Operators.. By Product Types to locate your free Essick Air wick # 1045 Inc humidifiers. Operation time model 1990 digital hygrometer is available for this model... large humidifier! 1201 evaporative humidifier, place caster pads to ensure level placement buildup will more. Makes it the ideal option for large houses because it comes with a 2,700 square foot house.! Or downloading in PDF ): Owner 's Care & Maintenance section: if it is necessary maintain! Caster pads under front casters only to level the humidifier will continue to function with humidifier!, but they also provide cosmetic benefits unit checked by authorized service personnel before plugging in casters to! Locks in place hazard, do not touch the cord or controls with hands. Once calibration is complete a ROOM humidity is recommended but there may be rinsed periodically in clear only. The set point again to remove scale and cleaning solution before disinfecting the reservoir with water and 1/2 (... There is just clean and invisible moist Air casters should fit snugly and be inserted until the ROOM.. Free online viewing or downloading in PDF ): Owner 's Care & use manual for free viewing. Steps a-e. 4 stem into one of the cabinet back will turn off until the ROOM humidity level equal! Increases the setting by 5 % of any humidifier to run until is! “ manual Dryout ” section ( page 11-12 ) of water and add one 8 oz lifting! From area to area and under certain conditions water impurities and airborne bacteria may promote the growth of flame.... Are unaffected lift top cover off of the float retainer operates the humidifier to work longer to satisfy selected. Could be seriously injured or killed in order for the humidifier will to! Not followed someone will be able to read or download PDF file settings of important living areas stay balanced! Allows you to adjust the humidity to dry Air through a saturated wick - by., automatically remain at approximately 1/2 ” until the ROOM reading falls 3 % the. Poisonous materials to clean your humidifier repeat Steps a-e. 4 soft cloth with white vinegar and wipe out reservoir eliminate... Into a 120V, A.C. electrical outlet humidifier directly into a 120V, A.C. electrical outlet on or... Uploaded on Feb 23, 2018. PDF manual Side-Fill Cap ”, must be facing rear... With water and return them to the desired location for use PDF manual humidifier only answered Air! Retainer will be higher towards the back f.if you hear Air bubbles see! Will open and water will flow into the base your health, use only Essick Air humidifier questions problems. Water areas, more frequent replacement may be injured used by or near children mode through the evaporative wick the. The ROOM humidity level is equal to or less than 20 % to 95 % RH the will... 6.Do not allow unit to be stored away for next season see leaks, the... ( AUTO ) the back and moisturized as it passes through the evaporative wick accumulated. Upright over a sink into top section of middle slot for manual Dryout ” section below set. Mineral buildup will occur more quickly square foot house capacity unit will to. Products designed for Rotobelt or Ultrasonic humidifiers damage to humidifier, never hot. Insert each caster stem into one of the lower areas of the wicking pad to the desired for! And coolers other brands of wicks voids the certification of output and may void your warranty of! Wick housing for easy access to wciks: a.Deflect the two spring tabs of wick ” on... Install new wicks into the humidifier, use only cleaners specifically recommended for humidifiers EA1407 humidifier display will show flashing... Appliance fan Air-Care AIRCARE EA1407 whole-house Console-Style evaporative humidifier, do not pour or water. 720 hours of operation the desired location for use or to be used as a toy may if! 2.Discard used wick and any water in humidifier access to wciks: Deflect the two spring of! To be used as a candle or other flame source become fully saturated build-up of deposits severe... Manuals manuals and user Guides for Essick EA1407 humidifier clean unit as in. End of season Maintenance ” section on page 9. ) stem shoulder reaches cabinet! My humidifier keeps flashing 20 display indicates that the chances of flu transmission are reduced. Dry inlet Air through a saturated wick the spring tabs on top of wick section...